city of San Antonio


Some of our meetings have moved. View additional meetings.

File #: 18-4387   
Type: Staff Briefing - Without Ordinance
In control: Planning Commission
On agenda: 7/25/2018
Posting Language: FPV #18-003: Request by Government Relations Group of TX for approval of a variance request associated with a Floodplain Development Permit (FPDP) #2018287 for an existing commercial tract (Zoned C-3) located at 3939 Thousand Oaks, at the northwest corner of Thousand Oaks and Salado Creek Tributary F, east of Bulverde Road. Staff recommends Approval. (Jacob Powell, Storm Water Engineering Manager, (210) 207-0176, jacob.powell@sanantonio.gov, Transportation and Capital Improvement Department)
Attachments: 1. Attachment #1- FPV 18-003 Bright Kids Daycare Center_Variance Support Letter_20180718, 2. AEVR_FPV #18-003_3939 Thousand Oaks, 3. Floodplain Variance Letter_7-14-18, 4. Exhibit A 3939 Thousand Oaks, 5. Exhibit A1 3939 Thousand Oaks, 6. Exhibit B to Variance Letter- FEMA Maps, 7. Exhibit C to Variance Letter - CEC, 8. FPDP #2018287- Denied & Signed, 9. 1984 Plat, 10. Property Info- 3939 Thousand Oaks
Date Ver.Action ByActionResultAction DetailsMeeting DetailsVideo
No records to display.

DEPARTMENT: Transportation & Capital Improvements

SUBJECT:
FPV# 18-003; FPDP #2018287 -3939 Thousand Oaks, Bright Kids Daycare Center #2

SUMMARY:
Request by Government Relations Group of TX for approval of a variance request associated with a Floodplain Development Permit (FPDP) #2018287 for an existing commercial tract (Zoned C-3) located at 3939 Thousand Oaks, at the northwest corner of Thousand Oaks and Salado Creek Tributary F, east of Bulverde Road. Staff recommends Approval. [(Jacob Powell, Storm Water Engineering Manager, (210) 207-0176, jacob.powell@sanantonio.gov, TCI Department)]

BACKGROUND INFORMATION:
Council District: District 10 - San Antonio
Filing Date: June 7, 2018
Owner: Mr. Padmasiri "Sam" Somawardana, Bright Kids Daycare Center #2
Agent: Mitsuko Ramos, Government Relations Group of TX
Staff Coordinator: Jacob Powell, Storm Water Engineering Manager, (210) 207-0176

ANALYSIS:

Variance Request:
On June 7, 2018, the applicant requested a variance from Sections 35-F124(f)(19) and 35-F133(6) in Appendix F of the Unified Development Code (UDC). The TCI Department, Storm Water Division has no objection to the granting of the variance as indicated in the attached letter (ATTACHMENT #1).

Substantial Damage/Improvement:
The structure at 3939 Thousand Oaks was substantially damaged by fire, and the owner is requesting to rebuild the structure. The site is currently within the regulatory 1% annual chance ultimate conditions (100-year future conditions) floodplain. The applicant provided survey information indicating that the existing finished floor elevation is below the base flood elevation (BFE) of the floodplain. The applicant is proposing to elevate the finished floor when reconstructing the building to a point at least one foot (1') above the floodplain, as per code.

However, Section 35-F124(f)(19) states that development may be allowed when, "Parking lot construction where water depths do not exceed si...